If you don't see the above menu, update to
|
|
THERMOCOUPLES & RESISTANCES - MGO-INSULATED TC - TECHNICAL DATA |
|
Types of MgO thermocouples |
|
Type |
Sensor Element |
Insulation |
Body material |
External diameter mm |
E |
Chromel/Constantan |
MgO |
AISI 304 - 900 °C |
0.25 - 0.5 - 1 - 1.5 - 2 3 - 4.5 - 6 - 8 -12.7 |
J |
Iron/Constantan |
AISI 310 - 1150 °C |
K |
Chromel/Alumel |
AISI 316 - 926 °C |
R |
Pt 13% Rh/Platinum |
AISI 321 - 900 °C |
T |
Copper/Constantan |
INCONEL 600 - 1150 °C |
Standard junctions of sensitive elements |
UNGROUNDED JUNCTION |
|
The sensing junction between the leads is totally insulated both electrically and mechanically from the body. Main application is in very hard-working conditions (with vibrations, thermal shocks, chemically aggressive environment, etc.) under which it provides a long working life. |
GROUNDED JUNCTION |
|
The sensing junction between the leads is directly welded on the body. This solution allows a good performance under pressure, high humidity and mechanical stress. Also, it is particulary recommended to get a fast response. |
EXPOSED JUNCTION |
|
Fast responce is the feature of this junction. It is reccommended for measurement of gas or solid surfaces in non-corrosive environmnts. |
Thermocouples working ranges | The temperature range depends on the thermocouple type, see below diagram:
Working ranges R = Pt 13% Rh/Platinum T = Copper/Constantan J = Iron/Constantan E = Chromel/Constantan K = Chromel/Alumel
|
Electrical signal of different thermocouples. |
|
TC001 Type J,K,T. Type of sensor: grounded-ungrounded-exposed. - Body material: AISI 321 for J and T, INCONEL 600 for K. - Body O.D. (mm): 0,25-0,5-1-1,5-2-3-4,5-6-8. - Lenght L: upon request. - Junction number: one or two. - Very flexible sensor |
|
|
TC002 Type J,K,T. Type of sensor: grounded-ungrounded-exposed. - Body material: AISI 321 for J and T, INCONEL 600 for K. - Body O.D. (mm): 0,25-0,5-1-1,5-2-3-4,5-6-8. - Lenght L: mm 300 standard, other on request. - Hot junction number: one or two. |
|
|
TC003 Standard plug probe. Type J,K,T. Type of sensor: grounded-ungrounded-exposed. - Body material: AISI 321 for J and T, INCONEL 600 for K. - Body O.D. (mm): 0,25-0,5-1-1,5-2-3-4,5-6-8. - Lenght L: mm 300 standard, other on request. - Hot junction number: one or two. |
|
|
TC004 Bayonet type thermocouples adjustable pressure contact. Type J,K,T. Type of sensing point: grounded-ungrounded-exposed. - Body material: AISI 321 for J and T, INCONEL 600 for K. - Body O.D. (mm): 1-1,5-2-3. |
|
|
TC006 Type J,K,T. Type of sensor: grounded-ungrounded-exposed. - Body material: AISI 321 for J and T, INCONEL 600 for K. - Body O.D. (mm): 0,25-0,5-1-1,5-2-3-4,5-6-8-12,7. - Lenght L: mm 300 standard, other on request. - Thread fitting:1/2”. - Hot junction number: one or two. | |
|
|
|
|